Case Studies

Real Water Pipe Leak Detection Cases

Each published case is based on an actual LeakPinpoint investigation. Customer identities and precise locations may be limited where privacy requires it.

Featured Case Study

See the problem, inspection and known result from our completed investigations. Some personal details and exact locations are withheld to protect customer privacy.

Residential Underground Water Leak Investigation

Residential Water Pipe Leak Investigation in Jitra, Kedah

The water bill exceeded RM600, and the meter kept moving after normal water use had stopped.

Location
Private Residential Property, Jitra, Kedah
System / property
Private residential property
Main investigation method
Acoustic ground microphone
The Result
After the pipe was exposed and repaired, the customer reported that the water meter was back to normal.
Read This Case

Residential Underground Water Leak Investigation

Shared Water Pipe Leak Investigation at Taman Naluri Indah

Unexplained water flow was reported in the shared supply serving common facilities.

Location
Taman Naluri Indah, Malaysia
System / property
Residential community management
Main investigation method
Acoustic ground microphone
The Result
The customer’s plumber exposed and repaired the pipe near the marked area. The management reported normal water meter operation after the repair.
Read This Case

Commercial / Industrial Water Pipeline Investigation

Underground Water Pipe Leak Investigation in Putrajaya

An earlier shallow excavation showed water but did not expose the damaged pipe. The approximately 100 mm HDPE pipe was about 2 metres below ground.

Location
Putrajaya, Malaysia
System / property
Institutional complex
Main investigation method
Acoustic ground microphone
The Result
Visible water may travel away from the damaged pipe. Deeper pipelines often require comparison at several accessible points. Pipe material, pressure, soil, access and background noise can affect the findings. A structured investigation can help reduce unnecessary excavation. The exact pipe condition is confirmed only after the pipe is exposed.
Read This Case

Fire Hydrant Pipeline Investigation

Two-Night Fire Main Leak Investigation at a Penang Factory

An underground fire-main network at an electronics manufacturing facility in Penang was investigated over two night-time sessions. The available evidence did not support one reliable excavation point.

Location
Penang, Malaysia
System / property
Electronics manufacturing facility
Main investigation method
Acoustic ground microphone
The Result
The results did not consistently point to one reliable digging location. We recorded the investigation as inconclusive and did not mark an unsupported leak point.
Read This Case

Additional completed projects will be published after their facts, photographs and customer permissions are confirmed.

Have a similar underground leak problem?

Send us the property or project type, location and what you have observed. Drawings, meter information and photographs are useful where available.

Request a Leak Assessment